{"id":117268,"date":"2026-03-09T19:44:29","date_gmt":"2026-03-09T18:44:29","guid":{"rendered":"https:\/\/www.packaging.si\/?p=117268"},"modified":"2026-03-09T19:44:29","modified_gmt":"2026-03-09T18:44:29","slug":"custom-bottle-wiper-for-12-3-mm-bottleneck","status":"publish","type":"post","link":"https:\/\/www.packaging.si\/pt\/custom-bottle-wiper-for-12-3-mm-bottleneck\/","title":{"rendered":"Redutor limpador personalizado para gargalo de 12.3 mm"},"content":{"rendered":"<p data-start=\"241\" data-end=\"359\">Recently we received a request from a client who uses <strong data-start=\"295\" data-end=\"356\">glass bottles with a bottleneck inner diameter of 12.3 mm<\/strong>.<\/p>\n<p data-start=\"361\" data-end=\"561\">Standard <strong data-start=\"370\" data-end=\"394\">DIN18 dropper wipers<\/strong> were not suitable for this bottle design, so we developed a <strong data-start=\"455\" data-end=\"474\">custom solution<\/strong> to ensure proper compatibility between the bottle, the wiper, and the dropper pipette.<\/p>\n<h2 data-section-id=\"1t3695u\" data-start=\"563\" data-end=\"592\">Optimized Wiper Dimensions<\/h2>\n<p data-start=\"594\" data-end=\"677\">To achieve a perfect fit, the wiper was designed with the following specifications:<\/p>\n<ul data-start=\"679\" data-end=\"806\">\n<li data-section-id=\"7jv702\" data-start=\"679\" data-end=\"722\">\n<p data-start=\"681\" data-end=\"722\"><strong data-start=\"681\" data-end=\"712\">Bottle inner neck diameter:<\/strong> 12.3 mm<\/p>\n<\/li>\n<li data-section-id=\"lje8fc\" data-start=\"723\" data-end=\"752\">\n<p data-start=\"725\" data-end=\"752\"><strong data-start=\"725\" data-end=\"742\">Wiper height:<\/strong> 15.6 mm<\/p>\n<\/li>\n<li data-section-id=\"rzbyha\" data-start=\"753\" data-end=\"806\">\n<p data-start=\"755\" data-end=\"806\"><strong data-start=\"755\" data-end=\"787\">Compatible pipette diameter:<\/strong> 7 mm glass pipette<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"808\" data-end=\"939\">These dimensions ensure smooth insertion of the wiper into the bottle while maintaining proper functionality of the dropper system.<\/p>\n<h2 data-section-id=\"ke8zt4\" data-start=\"941\" data-end=\"987\">Smooth Pipette Movement and Accurate Dosing<\/h2>\n<p data-start=\"989\" data-end=\"1121\">The internal opening of the wiper is optimized for <strong data-start=\"1040\" data-end=\"1063\">7 mm glass pipettes<\/strong>, allowing the pipette to pass smoothly through the wiper.<\/p>\n<p data-start=\"1123\" data-end=\"1166\">The wiper performs two important functions:<\/p>\n<ul data-start=\"1168\" data-end=\"1257\">\n<li data-section-id=\"1bl1elo\" data-start=\"1168\" data-end=\"1210\">\n<p data-start=\"1170\" data-end=\"1210\">removes excess liquid from the pipette<\/p>\n<\/li>\n<li data-section-id=\"1b7x1o\" data-start=\"1211\" data-end=\"1257\">\n<p data-start=\"1213\" data-end=\"1257\">helps ensure <strong data-start=\"1226\" data-end=\"1257\">clean and controlled dosing<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1259\" data-end=\"1315\">This is particularly important for applications such as:<\/p>\n<ul data-start=\"1317\" data-end=\"1416\">\n<li data-section-id=\"s0ug1a\" data-start=\"1317\" data-end=\"1336\">\n<p data-start=\"1319\" data-end=\"1336\">cosmetic serums<\/p>\n<\/li>\n<li data-section-id=\"5muw1b\" data-start=\"1337\" data-end=\"1355\">\n<p data-start=\"1339\" data-end=\"1355\">essential oils<\/p>\n<\/li>\n<li data-section-id=\"wkzor8\" data-start=\"1356\" data-end=\"1368\">\n<p data-start=\"1358\" data-end=\"1368\">CBD oils<\/p>\n<\/li>\n<li data-section-id=\"1p4pd68\" data-start=\"1369\" data-end=\"1395\">\n<p data-start=\"1371\" data-end=\"1395\">pharmaceutical liquids<\/p>\n<\/li>\n<li data-section-id=\"cvms50\" data-start=\"1396\" data-end=\"1416\">\n<p data-start=\"1398\" data-end=\"1416\">laboratory liquids<\/p>\n<\/li>\n<\/ul>\n<h2 data-section-id=\"1fqgjs0\" data-start=\"1418\" data-end=\"1444\">Testing and Performance<\/h2>\n<p data-start=\"1446\" data-end=\"1543\">The wiper was tested directly with the client\u2019s bottles and showed <strong data-start=\"1513\" data-end=\"1540\">excellent compatibility<\/strong>.<\/p>\n<p data-start=\"1545\" data-end=\"1712\">During the test, the pipette moves smoothly through the wiper while excess liquid is removed from the glass surface, preventing dripping and improving dosing accuracy.<\/p>\n<h2 data-section-id=\"vxzz3d\" data-start=\"1714\" data-end=\"1758\">Custom Solutions for Non-Standard Bottles<\/h2>\n<p data-start=\"1760\" data-end=\"1862\">Not all bottles follow the <strong data-start=\"1787\" data-end=\"1805\">DIN18 standard<\/strong>, which is why custom components are sometimes necessary.<\/p>\n<p data-start=\"1864\" data-end=\"2024\">If you are working with <strong data-start=\"1888\" data-end=\"1927\">non-standard bottle neck dimensions<\/strong>, we can help develop <strong data-start=\"1949\" data-end=\"1989\">custom wipers and dropper components<\/strong> tailored to your packaging system.<\/p>\n<h2 data-section-id=\"1qfa1f4\" data-start=\"2026\" data-end=\"2052\">Watch the Demonstration<\/h2>\n<p data-start=\"2054\" data-end=\"2209\">In the video below you can see how the <strong data-start=\"2093\" data-end=\"2208\">wiper fits into the bottle and how the pipette moves smoothly through the insert while excess liquid is removed<\/strong>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Recentemente recebemos um pedido de um cliente que utiliza frascos de vidro com um di\u00e2metro interior do gargalo de 12.3 mm. Os redutores limpadores DIN18 standard n\u00e3o eram adequados a este design de frasco, pelo que desenvolvemos uma solu\u00e7\u00e3o personalizada para garantir a compatibilidade correta entre o frasco, o redutor limpador e a pipeta do conta-gotas. Dimens\u00f5es otimizadas do redutor limpador Para conseguir&#8230;<\/p>","protected":false},"author":1,"featured_media":117269,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","footnotes":""},"categories":[550],"tags":[],"class_list":["post-117268","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-corporate-updates"],"_links":{"self":[{"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/posts\/117268","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/comments?post=117268"}],"version-history":[{"count":0,"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/posts\/117268\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/media\/117269"}],"wp:attachment":[{"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/media?parent=117268"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/categories?post=117268"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.packaging.si\/pt\/wp-json\/wp\/v2\/tags?post=117268"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}